REFRIGERATOR & FREEZER
The high-quality KIRSCH refrigerators and freezers are all used around the globe – in pharmacies, hospitals, clinics, blood banks, institutes and laboratories.Kirsch products are, Made in Germany“. All our products are manufactured in Germany and including select reliable suppliers located in Germany who also commit themselves to deliver the best quality
Download Catalog
!!! Lab refrigerator & Freezer !!!
!!! For Pharmaceutical !!!
!!! For Blood bank !!!
Blood Bank Refrigerators

Blood bank refrigerators are our most important products, they are subject to the 93/42/EEC directive (EC medical) .
In order to guarantee even higher safety and quality of our appliances, Kirsch is certified according to ISO 13485. This certificate proves the conformity to the relevant specifications in the manufacture of medical products. Each BL model offers numerous KIRSCH innovations as standard equipment. Manufactured according to DIN 58371.
Standard equipment
*DIN 58371
*PRO-ACTIVE Control
*Comfort controller
*High-adjustable drawers* **
*Aluminium drawers
*Automatic defrosting and condensate evaporation
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memory
*Temperature stability
*Digital and easy to read LED temperature display
*Re-circulating air cooling
*Potential free contact for alarm transmission.
* except BL 100 PRO-ACTIVE
** except BL 176 PRO-ACTIVE
ADVANTAGES
KIRSCH IS A MANUFACTURER, WHICH ENABLES US TO CONSISTENTLY DEVELOP OUR BLOOD BANK REFRIGERATORS. EACH UNIT CONSISTS OF A ROBUST HOUSING AND HIGH-QUALITY COMPONENTS MADE IN GERMANY. THIS ENSURES RELIABILITY AND A LONG SERVICE LIFE, WHICH ULTIMATELY SAVES YOUR BUDGET.
ULTIMATE

-
- 1634705069018
*Touch-Display, elegant glass design
*Simple operation via a capacitive touch display
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*Digital data documentation with KIRSCH Datanet software
*Quick-startTouch operation with laboratory gloves is possible
*Intuitive help with alarm messages and troubleshooting in plain text
*Operation via remote control is possible
*Including the benefits of the PRO-ACTIVE line
Blood Bank RefrigeratorBL 720 ULTIMATE
according to DIN 58371
In most of our blood bank fridges an LED batten light fitting can be installed at an extra cost which guarantees that the interior is well-lit. We are also able to supply lockable glass doors, so you can look inside without having to open the door.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*Touch-Display, elegant glass design, capacitive
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*5 aluminium drawers
*Castors
*Comfort controller
*Micro-processor controlled temperature and thawing regulation to maximizetemperature stability
*Battery for power failure alarm
*Re-circulation air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Drawers height-adjustable
*Easy-to-read LED temperature display
*Easy accessible control panel with key switch
*Optical and acoustical warning including power failure alarm
*Saftey control device prevents freezing
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH Datanet
*Lockable door
*Self closing glass door, lockable
*Additional drawer made of aluminium
*Adjustable feet to compensate for uneven floors.
*Drawer insert (Set) with 4 adjustable length and 40 cross dividers per drawer
*Additional length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawer
*Shelf 59,7 x 65 cm with mounting brackets or rails
*Baskets with rails 60 x 65 x 10 cm
*Aluminium tray with rails 60 x 65 x 2,5 cm
*LED illumination mounted at side wall
*Water tray for manual emptying
*Cooling machine with cold water connection
*Outer housing in stainless steel 4301, longitudinal brushed
Capacity | 700 l |
---|---|
Temperature setting | _+4 C |
Voltage | 220 - 240 V |
Frequency | 50 / 60 Hz |
Power consumption | 250 Watts |
Average consumption | 1,56 KWh / 24 h |
Overall dimensions incl. distance from wall | 77 x 98 x 195,5 (w x d x h in cm) |
Interior dimensions | 62 x 77 x 140 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 77 x 166 (w x d in cm) |
Drawer inner dimensions | 56 x 60 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 171 kg / 196 kg (net / gross) |
Blood Bank RefrigeratorBL 520 ULTIMATE
according to DIN 58371
This blood bank fridge features 5 vertically adjustable drawers made of aluminium as standard. A set with 4 adjustable longitudinal and 25 adjustable cross dividers for each drawer is optionally available.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*Touch-Display, elegant glass design, capacitive
*Access control with a log
*Graphical display of the Temperature curve and min/max temperature
*5 aluminium drawers
*Castors
*Full extension drawer
*Comfort controller
*Micro-processor controlled temperature and thawing regulation to maximizetemperature stability
*Battery for power failure alarm
*Re-circulation air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Drawers height-adjustable
*Easy-to-read LED temperature display
*Easy accessible control panel with key switch
*Optical and acoustical warning including power failure alarm
*Saftey control device prevents freezing
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH Datanet
*Low-noise compressor
*Lockable door
*Self closing glass door, lockable
*Additional drawer made of aluminium
*Adjustable feet to compensate for uneven floors.
*Drawer insert (Set) with 4 adjustable length and 25 cross dividers per drawer
*Additional length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawer
*Shelf 59,7 x 45 cm with mounting brackets or rails
*Baskets with rails 60 x 45 x 10 cm
*Aluminium tray with rails 60 x 40 x 2,5 cm
*LED illumination mounted at side wall
*Water tray for manual emptying
*Cooling machine with cold water connection
*Outer housing in stainless steel 4301, longitudinal brushed
Capacity | 500 l |
---|---|
Temperature setting | _+4 C |
Voltage | 220 - 240 V |
Frequency | 50 / 60 Hz |
Power consumption | 250 Watts |
Average consumption | 1,56 KWh / 24 h |
Overall dimensions incl. distance from wall | 77 x 76 x 195,5 (w x d x h in cm) |
Interior dimensions | 62 x 56 x 140 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 77 x 144 (w x d in cm) |
Drawer inner dimensions | 56 x 39 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 139 kg / 160 kg (net / gross) |
Blood Bank RefrigeratorBL 300 ULTIMATE
according to DIN 58371, medical product certified according to DIN ISO 13485
This blood bank refrigerator has a door handle which features a mechanism for easy opening. If the refrigerator is used in hygienically demanding areas melt water trays for manual emptying are available for all blood bank refrigerators.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*Touch-Display, elegant glass design, capacitive
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*4 aluminium drawers
*Comfort controller
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Battery for power failure alarm
*Re-circulation air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Automatic defrosting
*Melt water evaporation
*Drawers height-adjustable
*Easy-to-read LED temperature display
*Easy accessible control panel with key switch
*Optical and acoustical warning including power failure alarm
*Saftey control device prevents freezing
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH Datanet
*Lockable door
*Glass door with lock
*Castors
*Additional drawer made of aluminium
*Drawer insert (Set) with 3 adjustable length and 24 adjustable (drawer below 16) cross dividers
*Additional length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawer
*Shelf 52,7 x 39 cm with mounting brackets or rails
*LED illumination mounted on top
*Water tray for manual emptying (stacking height of the drawer below then only 19 cm)
Capacity | 280 l |
---|---|
Temperature setting | _+4 C |
Voltage | 220 - 240 V |
Frequency | 50 / 60 Hz |
Power consumption | 95 Watts |
Average consumption | 0,63 KWh / 24 h |
Overall dimensions incl. distance from wall | 67 x 75 x 131 (w x d x h in cm) |
Interior dimensions | 55 x 51 x 100 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 67 x 133 (w x d in cm) |
Drawer inner dimensions | 49 x 39 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 802 kg / 92 kg (net / gross) |
PRO-ACTIVE

*Reduction in power consumption by up to 60%
*Faster response times in case of impending faults thanks to proactive alerts
*Data documentation can be read via USB interface with KIRSCH Datanet software
*Reduction in temperature deviations in the refrigerated compartment
*Maximum storage safety due to perfectly coordinated components
*Including the benefits of the ESSENTIAL line
Blood Bank RefrigeratorBL 720 PRO-ACTIVE
according to DIN 58371
In most of our blood bank fridge an LED batten light fitting can be installed at an extra cost which guarantees that the interior is well-lit. We are also able to supply lockable glass doors, so you can look inside without having to open the door.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*5 aluminium drawers
*Castors
*Comfort controller
*Micro-processor controlled temperature and thawingregulation to maximize temperature stability
*Battery for power failure alarm
*Re-circulating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memory
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Potential free contact for alarm transmission
*Lockable door
*Self closing glass door, lockable
*Additional drawer made of aluminium
*Adjustable feet to compensate for uneven floors.
*Drawer insert (Set) with 4 adjustable length and 40 cross dividers per drawer
*Additional length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawer
*Shelf 59,7 x 65 cm with mounting brackets or rails
*Baskets with rails 60 x 65 x 10 cm
*Aluminium tray with rails 60 x 65 x 2,5 cmLED illumination mounted at side wall
*Water tray for manual emptying
*GSM-Module
*Cooling machine with cold water connection
*Outer housing in stainless steel 4301, longitudinal brushed
*PC-KIT-NET (Network capable version)
*Pen-Recording thermometer for placing loosely inside appliance with waxed paper strips
*Disc-type pen recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 700 l |
---|---|
Temperature setting | _+4 C |
Voltage | 220 - 240 V |
Frequency | 50 / 60 Hz |
Power consumption | 250 Watts |
Average consumption | 1,56 KWh / 24 h |
Overall dimensions incl. distance from wall | 77 x 98 x 195,5 (w x d x h in cm) |
Interior dimensions | 62 x 77 x 140 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 77 x 166 (w x d in cm) |
Drawer inner dimensions | 56 x 60 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 171 kg / 196 kg (net / gross) |
Blood Bank RefrigeratorBL 520 PRO-ACTIVE
according to DIN 58371
This blood bank fridge features 5 vertically adjustable drawers made of aluminium as standard. A set with 4 adjustable longitudinal and 25 adjustable cross dividers for each drawer is optionally available.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*5 aluminium drawers
*Castors
*Comfort controller
*Micro-processor controlled temperature and thawingregulation to maximize temperature stability
*Battery for power failure alarm
*Re-circulating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memory
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Potential free contact for alarm transmission
*Lockable door
*Self closing glass door, lockable
*Adjustable feet to compensate for uneven floors.
*Additional drawer made of aluminium
*Drawer insert (Set) with 4 adjustable length and 25 cross dividers per drawer
*Additional length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawer
*Shelf 59,7 x 45 cm with mounting brackets or railsBaskets with rails 60 x 45 x 10 cm
*Aluminium tray with rails 60 x 40 x 2,5 cm
*LED illumination mounted at side wall
*Water tray for manual emptying
*GSM-Module
*Cooling machine with cold water connection
*Outer housing in stainless steel 4301, longitudinal brushed
*PC-KIT-NET (Network capable version)
*Pen-Recording thermometer for placing loosely inside appliance with waxed paper strips
*Disc-type pen recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 500 l |
---|---|
Temperature setting | _+4 C |
Voltage | 220 - 240 V |
Frequency | 50 / 60 Hz |
Power consumption | 250 Watts |
Average consumption | 1,5 KWh / 24 h |
Overall dimensions incl. distance from wall | 77 x 76 x 195,5 (w x d x h in cm) |
Interior dimensions | 62 x 56 x 140 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 77 x 144 (w x d in cm) |
Drawer inner dimensions | 56 x 39 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 139 kg / 160 kg (net / gross) |
Blood Bank RefrigeratorBL 300 PRO-ACTIVE
according to DIN 58371, medical product certified according to DIN ISO 13485
Our blood bank fridges can be connected to the central control unit via the potential-free contacts which are integrated as standard. A device for data evaluation can be connected to the integrated RS-485 interface.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*5 aluminium drawers
*Castors
*Comfort controller
*Micro-processor controlled temperature and thawingregulation to maximize temperature stability
*Battery for power failure alarm
*Re-circulating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memory
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Potential free contact for alarm transmission
*Lockable door
*Castors
*Drawer insert (Set) with adjustabel length and 21 cross dividers per drawer
*Additional length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawer
*LED illumination mounted on top
*Water tray for manual emptying
*GSM-Module
*PC-KIT-NET (Network capable version)
*Pen-Recording thermometer for placing loosely inside appliance with waxed paper strips
*Disc-type pen recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens (refrigerator height then 131 cm)
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 280 l |
---|---|
Temperature setting | _+4 C |
Voltage | 220 - 240 V |
Frequency | 50 / 60 Hz |
Power consumption | 95 Watts |
Average consumption | 0,63 KWh / 24 h |
Overall dimensions incl. distance from wall | 67 x 75 x 124 (w x d x h in cm) |
Interior dimensions | 55 x 51 x 100 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 67 x 133 (w x d in cm) |
Drawer inner dimensionns of 3 upper drawers | 49 x 39 x 10 (w x d x h in cm) |
Drawer inner dimensions of the drawer below | 51 x 31 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 139 kg / 160 kg (net / gross) |
Blood Bank RefrigeratorBL 176 PRO-ACTIVE
according to DIN 58371, medical product certified according to DIN ISO 13485
Our blood bank fridges can be connected to the central control unit via the potential-free contacts which are integrated as standard. A device for data evaluation can be connected to the integrated RS-485 interface.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*2 aluminium drawers
*Comfort controller
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Battery for power failure alarm
*Re-circulation air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Automatic defrosting
*Melt water evaporation
*Easy-to-read LED temperature display
*Easy accessible control panel with key switch
*Optical and acoustical warning including power failure alarm
*Minimum/Maximum temperature memory
*Saftey control device prevents freezing
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Lockable door
*Castors
*Drawer insert (Set) with adjustabel length and 21 cross dividers per drawer
*Additional length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawer
*LED illumination mounted on topWater tray for manual emptying
*GSM-Module
*PC-KIT-NET (Network capable version)
*Pen-Recording thermometer for placing loosely inside appliance with waxed paper strips
*Disc-type pen recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens (refrigerator height then 131 cm)
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 170 l |
---|---|
Temperature setting | _+4 C |
Voltage | 220 - 240 V |
Frequency | 50 / 60 Hz |
Power consumption | 120 Watts |
Average consumption | 1,22 KWh / 24 h |
Overall dimensions incl. distance from wall | 70 x 77 x 122 (w x d x h in cm) |
Interior dimensions | 55 x 52 x 60 (w x d x h in cm) |
Usable dimensions | 53 x 41 x 47 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 70 x 136 (w x d in cm) |
Drawer inner dimensionns | 50 x 34 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 77 kg / 87 kg (net / gross) |
Blood Bank RefrigeratorBL 100 PRO-ACTIVE
according to DIN 58371, medical product certified according to DIN ISO 13485
This blood bank fridge can be installed normally and also in an undercounter-type installation. Door coupling fittings or decorative frames are available at an extra cost. When the device is being installed as a stand-alone unit we can optionally supply a matching tabletop.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*2·drawers
*Undercounter type
*Comfort controller
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Battery for power failure alarm
*Re-circulation air-cooling
*Automatic defrosting
*Melt water evaporation
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning signal including power failure alarm
*Minimum/Maximum temperature memory
*Saftey control device prevents freezing
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Low-noise compressor
*Lockable door
*Insulating glass door with lock
*Work surface
*Decorative door frame
*Door fitting
*Castors
*Water tray for manual emptying
*GSM-Module
*PC-KIT-NET (Network capable version)
*Pen-Recording thermometer for placing loosely inside appliance with waxed paper strips
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 95 l |
---|---|
Temperature setting | _+4 C |
Voltage | 220 - 240 V |
Frequency | 50 / 60 Hz |
Power consumption | 92 Watts |
Average consumption | 0,64 KWh / 24 h |
Overall dimensions incl. distance from wall | 54 x 54 x 82 (w x d x h in cm) |
Interior dimensions | 44 x 43 x 47 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 50 x 106 (w x d in cm) |
Drawer inner dimensionns | 37 x 32 x 8.5 (w x d x h in cm) |
Loading capacity per drawer | 25 kg |
Weight | 46 kg / 55 kg (net / gross) |
Blood Plasma Freezers

BL models are our top products. Each blood plasma freezer is particularly highly insulated and offers numerous KIRSCH innovations as standard equipment. To ensure the highest possible safety and quality of our blood equipment, Kirsch is certified according to ISO 13485. This certification proves compliance with the relevant regulations for the manufacture of medical products.Manufactured according to DIN 58375.
ADVANTAGES
KIRSCH is manufacturer. This enables us to develop our blood plasma freezer constantly. Each device consists of a robust housing and high quality components “Made in Germany”. This guarantees reliability and a long economic life-time which in return saves your money.
Standard equipment:
*DIN 58375 compliant
*Aluminium / stainless steel drawersComfort controller
*Micro-processor controlled temperature and thawing regulation to maximizetemperature stability
*Battery for power failure alarm
*Heated door frameRe-circulating air cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Height-adjustable drawers*
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memory
*RS-485 interface for computer based temperature documentation
*Potential free contact for alarm transmission.
*Except FROSTER-BL-178, FROSTER-BL-180 and FROSTER-BL-650.

1.TemperatureWe provide blood plasma freezers with temperatures of – 32°C or – 41°C.
2.IsolationThe housing is insulated with particulary good, environmentally-compatible pressure foam material to guarantee low energy consumption levels.
3.Interior ContainerThe interior is made of smooth aluminium with a transparent protective coating.
4.Interior EquipmentThe aluminium container features shelve mountings in which the drawers can be hanged in. The distance of these mountings can be altered in 15 mm steps (these mountings are height-adjustable).
5.DoorThe lockable door has a plastic magnetic sealing frame that is easy to replace. Door hinged on the right as standard, however this can be changed to the left at later date.
Built According to· DIN 58375 Regulation
A re-circulating air cooling system is integrated as standard and reduces the physically induced temperature drop and enables an almost constant temperature to be maintained in the freezers.
Blood plasma freezers with -32 °C and -40 °C are available for plasma storage. The temperature is maintained automatically by an electronic, micro-processor controlled temperature regulator, even in the event of changing ambient temperatures. Rapid defrosting with thermal and temporal monitoring takes place automatically. The required plasma storage temperature is maintained thanks to the reversing of the refrigerant circuit.
The standard equipment features of KIRSCH blood plasma freezers include an electronic switching, monitoring and warning device, a minimum/maximum temperature memory, an RS485 interface and a potential-free contact for connection to the central control technology.
ULTIMATE

-
- 1634705069018
*Touch-Display, elegant glass design
*Simple operation via a capacitive touch display
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*Digital data documentation with KIRSCH Datanet software
*Quick-start
*Touch operation with laboratory gloves is possible
*Intuitive help with alarm messages and troubleshooting in plain text
*Operation via remote control is possible
*Including the benefits of the PRO-ACTIVE line
Blood Plasma FreezerFROSTER BL 730 ULTIMATE
according to DIN 58375
Selected models can be fitted with a water-cooled refrigeration machine on request. The generated heat gets derived into a cold water cycle, which is already installed in the device. This provides thermal relief in the installation room.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*Touch-Display, elegant glass design, capacitive
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*5 aluminium drawers
*Castors
*Full extension drawer
*Comfort controller
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Battery for power failure alarm
*Heated door frame
*Re-circulation air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Height-adjustable drawers
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH Datanet
*Potential free contact for alarm transmission
*Lockable door
*Additional drawer made of aluminium
*Adjustable feet to compensate for uneven floors.
*Length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawer
*Shelf 59,7 x 65 cm with mounting brackets or rails
*Baskets with rails 60 x 65 x 10 cm
*Aluminium tray with rails 60 x 65 x 2,5 cm
*Outer housing in stainless steel 4301, brushed
Capacity | 700 l |
---|---|
Temperature setting | -32°C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 790 Watts |
Average consumption | 11,1 KWh / 24 h |
Overall dimensions incl. distance from wall | 77 x 98 x 195,5 (w x d x h in cm) |
Interior dimensions | 62 x 77 x 140 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 77 x 166 (w x d in cm) |
Drawer inner dimensionns | 56 x 60 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 202 kg / 237 kg (net / gross) |
Blood Plasma FreezerFROSTER BL 530 ULTIMATE
according to DIN 58375
For all blood plasma freezers a PC-Kit is available for temperature evaluation, monitoring and documentation. Monitoring can also be done with the KIRSCH-DATANET Software-package. You find more information on this software in the corresponding description “KIRSCH-PC-KIT”.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*Touch-Display, elegant glass design, capacitiveAccess control with a log
*Graphical display of the temperature curve and min/max temperature
*5 aluminium drawers
*Castors
*Full extension drawer
*Comfort controller
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Battery for power failure alarm
*Heated door frame
*Re-circulation air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Height-adjustable drawers
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH Datanet
*Potential free contact for alarm transmission
*Lockable door
*Additional drawer made of aluminium
*Adjustable feet to compensate for uneven floors.
*Length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawer
*Shelf 59,7 x 45 cm with mounting brackets or rails
*Baskets with rails 60 x 45 x 10 cm
*Aluminium tray with rails 60 x 40 x 2,5 cm
Capacity | 500 l |
---|---|
Temperature setting | -32°C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 740 Watts |
Average consumption | 10,81 KWh / 24 h |
Overall dimensions incl. distance from wall | 77 x 76 x 195,5 (w x d x h in cm) |
Interior dimensions | 62 x 56 x 140 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 77 x 144 (w x d in cm) |
Drawer inner dimensionns | 56 x 39 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 161 kg / 183 kg (net / gross) |
Blood Plasma FreezerFROSTER BL 330 ULTIMATE
according to DIN 58375
This model features 4 vertically adjustable drawers made of aluminium which rest on telescopic runners. Drawers made of stainless steel are optionally available. We also supply dividers for a neatly and clearly arranged storage of the goods for both types of drawers.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*Touch-Display, elegant glass design, capacitive
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*4 aluminium drawers
*Comfort controller
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Battery for power failure alarm
*Heated door frame
*Re-circulation air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Height-adjustable drawers
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH Datanet
*Potential free contact for alarm transmission
*Lockable door
*Castors
*Additional drawer made of aluminium
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawer
*Shelf 52 x 42 cm with mounting brackets or rails
*Baskets with rails 56 x 40 x 10 cm
*Length and cross dividers
Capacity | 300 l |
---|---|
Temperature setting | -32°C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 550 Watts |
Average consumption | 6,59 KWh / 24 h |
Overall dimensions incl. distance from wall | 74 x 78 x 166 (w x d x h in cm) |
Interior dimensions | 59 x 52 x 95 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 74 x 142 (w x d in cm) |
Drawer inner dimensionns | 54 x 37 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 120 kg / 135 kg (net / gross) |
PRO-ACTIVE

*Reduction in power consumption by up to 60%
*Faster response times in case of impending faults thanks to proactive alerts
*Data documentation can be read via USB interface with KIRSCH Datanet software
*Reduction in temperature deviations in the refrigerated compartment
*Maximum storage safety due to perfectly coordinated components
*Including the benefits of the ESSENTIAL line
FROSTER BL 730 PRO-ACTIVE
according to DIN 58375
Selected models can be fitted with a water-cooled refrigeration machine on request. The generated heat gets derived into a cold water cycle, which is already installed in the device. This provides thermal relief in the installation room.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*5 aluminium drawers
*Castors
*Comfort controller
*Micro-processor controlled temperature and thawingregulation to maximize temperature stability
*Battery for power failure alarm
*Heated door frame
*Re-circulating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memory
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Potential free contact for alarm transmission
*Lockable door
*Additional drawer made of aluminium
*Adjustable feet to compensate for uneven floors.
*Length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawerShelf 59,7 x 65 cm with mounting brackets or rails
*Baskets with rails 60 x 65 x 10 cm
*Aluminium tray with rails 60 x 65 x 2,5 cm
*GSM-Module
*Outer housing in stainless steel 4301, brushed
*Pen-Recording thermometer for placing loosely inside appliance with waxed paper strips
*Disc-type pen recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 700 l |
---|---|
Temperature setting | -32°C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 790 Watts |
Average consumption | 11,1 KWh / 24 h |
Overall dimensions incl. distance from wall | 77 x 98 x 195,5 (w x d x h in cm) |
Interior dimensions | 62 x 77 x 140 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 77 x 166 (w x d in cm) |
Drawer inner dimensionns | 56 x 60 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 202 kg / 237 kg (net / gross) |
FROSTER BL 650 PRO-ACTIVE
according to DIN 58375
Storage temperature of this freezer is -41°C. A two-stage refrigeration machine generates the necessary cooling so that this temperature is kept constant. This enables operation of the freezer in ambient temperatures of up to +32°C.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*5 stainless steel drawers
*Comfort controller
*Micro-processor controlled temperature and thawing
*regulation to maximize temperature stabilityBattery for power failure alarm
*Heated door frame
*Re-circulation air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memory
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Potential free contact for alarm transmission
*Lockable door
*Drawer insert/dividers for stainless steel drawer
*GSM-Module
*PC-KIT-NET (Network capable version)
*Disc-type pen recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 650 l |
---|---|
Temperature setting | -41°C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 990 Watts |
Average consumption | 14,32 KWh / 24 h |
Overall dimensions incl. distance from wall | 83 x 102 x 197 (w x d x h in cm) |
Interior dimensions | 62 x 76 x 131 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 83 x 177 (w x d in cm) |
Drawer inner dimensionns, upper drawers | 59 x 56 x 22 (w x d x h in cm) |
Drawer inner dimensionns, 4 drawers below | 59 x 62 x 22 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 202 kg / 237 kg (net / gross) |
FROSTER BL 530 PRO-ACTIVE
according to DIN 58375
For all blood plasma freezers a PC-Kit is available for temperature evaluation, monitoring and documentation. Monitoring can also be done with the KIRSCH-DATANET Software-package. You find more information on this software in the corresponding description “KIRSCH-PC-KIT”.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*5 aluminium drawers
*Castors
*Comfort controller
*Micro-processor controlled temperature and thawing
*regulation to maximize temperature stability
*Battery for power failure alarmHeated door frame
*Re-circulation air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Height-adjustable drawers
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memo
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Potential free contact for alarm transmission
*Lockable door
*Additional drawer made of aluminium
*Adjustable feet to compensate for uneven floors.
*Length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawer
*Shelf 59,7 x 45 cm with mounting brackets or rails
*Baskets with rails 60 x 45 x 10 cm
*Aluminium tray with rails 60 x 40 x 2,5 cm
*GSM-Module
*Outer housing in stainless steel 4301, brushed
*Pen-Recording thermometer for placing loosely inside appliance with waxed paper strips
*Disc-type pen recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 500 l |
---|---|
Temperature setting | -32°C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 740 Watts |
Average consumption | 10,81 KWh / 24 h |
Overall dimensions incl. distance from wall | 77 x 76 x 195,5 (w x d x h in cm) |
Interior dimensions | 62 x 56 x 140 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 77 x 144 (w x d in cm) |
Drawer inner dimensionns | 56 x 39 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 161 kg / 183 kg (net / gross) |
FROSTER BL 330 PRO-ACTIVE
according to DIN 58375
This model features 4 vertically adjustable drawers made of aluminium which rest on telescopic runners. Drawers made of stainless steel are optionally available. We also supply dividers for a neatly and clearly arranged storage of the goods for both types of drawers.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*4 aluminium drawers
*Comfort controller
*Micro-processor controlled temperature and thawingregulation to maximize temperature stability
*Battery for power failure alarm
*Heated door frame
*Re-circulating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memory
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Potential free contact for alarm transmission
*Lockable door
*Castors*Length and cross dividers
*Additional drawer made of aluminium
*Drawer made of stainless steel instead of aluminium
*Shelf 52 x 42 cm with mounting brackets or rails
*Baskets with rails 56 x 40 x 10 cm
*Drawer insert/dividers for stainless steel drawer
*GSM-Module
*PC-KIT-NET (Network capable version)
*Pen-Recording thermometer for placing loosely inside appliance with 2 waxed paper strips
*Disc-type pen recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens (refrigerator height then 131 cm)
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 300 l |
---|---|
Temperature setting | -32°C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 550 Watts |
Average consumption | 6,59 KWh / 24 h |
Overall dimensions incl. distance from wall | 74 x 78 x 159 (w x d x h in cm) |
Interior dimensions | 59 x 52 x 95 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 74 x 142 (w x d in cm) |
Drawer inner dimensionns | 50 x 37 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 120 kg / 135 kg (net / gross) |
FROSTER BL 180 PRO-ACTIVE
according to DIN 58375
All KIRSCH Blood Plasma Freezers are fitted with an automatic rapid defrosting system. The defrosting process is thermically monitored and temporarily limited. This prevents freezing of the interior and the temperature of the appliance’s contents is being kept constant in accordance with applicable regulations.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*3 aluminium drawers
*Comfort controller
*Micro-processor controlled temperature and thawingregulation to maximize temperature stability
*Battery for power failure alarm
*Heated door frame
*Re-circulating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memory
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Potential free contact for alarm transmission
*Lockable door
*Castors
*Additional length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawer
*GSM-Module
*PC-KIT-NET (Network capable version)
*Pen-Recording thermometer for placing loosely inside appliance with 2 waxed paper strips
*Disc-type pen recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens (refrigerator height then 131 cm)
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 170 l |
---|---|
Temperature setting | -41°C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 453 Watts |
Average consumption | 6,54 KWh / 24 h |
Overall dimensions incl. distance from wall | 70 x 77 x 122 (w x d x h in cm) |
Interior dimensions | 55 x 52 x 60 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 70 x 136 (w x d in cm) |
Drawer inner dimensionns | 50 x 32 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 100 kg / 110 kg (net / gross) |
FROSTER BL 178 PRO-ACTIVE
according to DIN 58375
All KIRSCH Blood Plasma Freezers are fitted with an automatic rapid defrosting system. The defrosting process is thermically monitored and temporarily limited. This prevents freezing of the interior and the temperature of the appliance’s contents is being kept constant in accordance with applicable regulations.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*3 aluminium drawers
*Comfort controller
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Battery for power failure alarm
*Heated door frame
*Re-circulating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memory
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Potential free contact for alarm transmission
*Lockable door
*Castors
*Additional length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawer
*GSM-Module
*PC-KIT-NET (Network capable version)
*Pen-Recording thermometer for placing loosely inside appliance with 2 waxed paper strips
*Disc-type pen recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens (refrigerator height then 131 cm)
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 170 l |
---|---|
Temperature setting | -32°C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 500 Watts |
Average consumption | 4,54 KWh / 24 h |
Overall dimensions incl. distance from wall | 70 x 77 x 122 (w x d x h in cm) |
Interior dimensions | 55 x 52 x 60 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 70 x 136 (w x d in cm) |
Drawer inner dimensionns | 50 x 34 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 100 kg / 110 kg (net / gross) |

Refrigerators for pharmaceuticals and vaccines according to DIN 58345
Are you looking for safe storage for medicines and vaccines?
KIRSCH is the market leader for pharmaceutical refrigerators in Germany. Each refrigerator is particularly made to meet the demanding DIN 58345 regulation. Our products are market leading in temperature stability and quality.
The average value of storage goods in a medicine refrigerator is 20.000€. To this day, the vaccines are improperly stored in household refrigerators resulting in spoils due to fluctuating temperatures. Tainted vaccines are at best no longer effective, at worst they lead to complications when vaccinated. This has to change, because the safety of your patients is priceless.
The pharmaceutical refrigerators according to DIN norm guarantee the maximum temperature consistency and storage safety. Because not everything always runs smoothly, according to DIN norm the refrigerators must also be equipped with safety features, e.g. warnings in case of power failure, temperature deviations, etc. that no household refrigerators have. Furthermore, the state-of-the-art refrigerators (ULTIMATE line) are also equipped with access control monitoring system to prevent your valuable goods being taken and/or modified by unauthorized personnel.
All KIRSCH pharmaceutical refrigerators of the ULTIMATE and PRO-ACTIVE lines are designed to meet the requirements of DIN 58345. In fact, as a pioneer in the construction of pharmaceutical refrigerators, our devices met all those requirements even before DIN was introduced. Every avoided case of tainted medicines or vaccines increases patient safety and saves you trouble and money.

YOUR ADVANTAGES
Depending on the individual model type, the refrigerators also feature:
*Re-circulating air cooling
*Optimized ventilation plates to minimize interior temperature differences
*Easy-to-read LED temperature display
*Automatical defrosting and melt water evaporation
*Easy accessible control panel with key switch
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Optical and acoustical alarm including power failure alarm*Minimum/maximum temperature memorySafety device to prevent freezing
*RS485 interface for computer based temperature documentation
*Potential free contact for alarm transmission
*Height-adjustable drawers
*Individual drawer division with adjustable length and cross dividers.
*Low-noise compressor
Glass doors are available for most models, as well as a decorative installation frame or door coupling fittings.
The average value of storage goods in a medicine refrigerator is 20.000€. To this day, the vaccines are improperly stored in household refrigerators resulting in spoils due to fluctuating temperatures. Tainted vaccines are at best no longer effective, at worst they lead to complications when vaccinated. This has to change, because the safety of your patients is priceless.
The pharmaceutical refrigerators according to DIN norm guarantee the maximum temperature consistency and storage safety. Because not everything always runs smoothly, according to DIN norm the refrigerators must also be equipped with safety features, e.g. warnings in case of power failure, temperature deviations, etc. that no household refrigerators have. Furthermore, the state-of-the-art refrigerators (ULTIMATE line) are also equipped with access control monitoring system to prevent your valuable goods being taken and/or modified by unauthorized personnel.
All KIRSCH pharmaceutical refrigerators of the ULTIMATE and PRO-ACTIVE lines are designed to meet the requirements of DIN 58345. In fact, as a pioneer in the construction of pharmaceutical refrigerators, our devices met all those requirements even before DIN was introduced. Every avoided case of tainted medicines or vaccines increases patient safety and saves you trouble and money.
ULTIMATE

-
- 1634705069018
*Touch-Display, elegant glass design
*Simple operation via a capacitive touch display
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*Digital data documentation with KIRSCH Datanet software
*Quick-start
*Touch operation with laboratory gloves is possible
*Intuitive help with alarm messages and troubleshooting in plain text
*Operation via remote control is possible
*Including the benefits of the PRO-ACTIVE line
Pharmaceutical RefrigeratorMED 720 ULTIMATE
according to DIN 58345
The pharmaceutical fridge features 12 vertically adjustable drawers made of aluminium as standard equipment. The drawers rest on telescopic runners and have a locking element. Each drawer has 2 adjustable length dividers and 9 adjustable cross dividers.

*PRO-ACTIVE- Control:
Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors.
*Touch-Display, elegant glass design, capacitive
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*12 drawers, height adjustable
*Individual drawer division with adjustable length and cross dividers.
*Recirculating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Automatic defrosting
*Melt water evaporation
*Easy-to-read LED temperature display
*Easy accessible control panel with key switchMicro-processor controlled temperature and thawing regulation to maximize temperature stability
*Minimum/Maximum temperature memory
*Safety control prevents freezing
*Optical and acoustical alarm including power failure alarm
*Potential free contact for alarm transmission
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH
Datanet
*Lockable door
*Glass door with lock
*Decorative frame
*Castors
*Additional drawers on rails, max. capacity of drawers per fridge: 8 drawers
*Additional length and cross dividers
*Shelf on rails or brackets (max. loading capacity: 40 kg)
*LED illumination mounted on top
*Melt water tray for manual emptying
Capacity | 700 l |
---|---|
Temperature setting | +2 to +15 °C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 250 Watts |
Average consumption | 1,55 KWh / 24 h |
Overall dimensions incl. distance from wall | 77 x 98 x 195,5 (w x d x h in cm) |
Interior dimensions | 62 x 77 x 140 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 77 x 165 (w x d in cm) |
Drawer inner dimensionns | 57 x 60 x 6 (w x d x h in cm) |
Loading capacity per drawer | 24 kg |
Weight | 164 kg / 190 kg (net / gross) |
Product information
Operating instructions
Please note:
You will find the information about the refrigerant used in your unit on the type plate inside the unit (R134a or R600a)
Operating instructions MED 720 ULTIMATE
Pharmaceutical RefrigeratorMED 520 ULTIMATE
according to DIN 58345
The pharmaceutical fridge features 12 vertically adjustable drawers made of plastic as standard equipment. The drawers rest on telescopic runners and have a locking element. Each drawer has 2 adjustable length dividers and 12 adjustable cross dividers.

*PRO-ACTIVE- Control:
Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors.
*Touch-Display, elegant glass design, capacitive
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*12 drawers, height adjustableIndividual drawer division with adjustable length and cross dividers.
*Recirculating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Automatic defrosting
*Melt water evaporation
*Easy-to-read LED temperature display
*Easy accessible control panel with key switch
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Safety control prevents freezing
*Optical and acoustical alarm including power failure alarm
*Potential free contact for alarm transmission
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH Datanet
*Lockable door
*Glass door with lock
*Decorative frame
*Castors
*Additional drawers on rails, max. capacity of drawers per fridge: 8 drawers
*Additional length and cross dividers
*Top drawer lockble
*Shelf on rails or brackets (max. loading capacity: 40 kg)
*LED illumination mounted at side wall
*Melt water tray for manual emptying
Capacity | 500 l |
---|---|
Temperature setting | +2 to +15 °C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 260 Watts |
Average consumption | 1,5 KWh / 24 h |
Overall dimensions incl. distance from wall | 77 x 76 x 196 (w x d x h in cm) |
Interior dimensions | 60 x 57 x 140 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 77 x 144 (w x d in cm) |
Drawer inner dimensionns | 57 x 37 x 5,6 (w x d x h in cm) |
Loading capacity per drawer | 24 kg |
Weight | 120 kg / 174 kg (net / gross) |
Product information
Operating instructions
Please note:
You will find the information about the refrigerant used in your unit on the type plate inside the unit (R134a or R600a)
Operating instructions MED 520 ULTIMATE
Pharmaceutical RefrigeratorMED 468 ULTIMATE (on request)
according to DIN 58345
The pharmaceutical fridge features 10 vertically adjustable drawers made of plastic as standard equipment. The drawers rest on telescopic runners and have a locking element. Each drawer has 2 adjustable length dividers and 12 adjustable cross dividers.

*PRO-ACTIVE- Control:
Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors.
*Touch-Display, elegant glass design, capacitive
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*10 drawers, height adjustable
*Individual drawer division with adjustable length and cross dividers.
*Recirculating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Automatic defrosting
*Melt water evaporation
*Easy-to-read LED temperature display
*Easy accessible control panel with key switch
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Safety control prevents freezing
*Optical and acoustical alarm including power failure alarm
*Potential free contact for alarm transmission
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH Datanet
*Lockable door
*Glass door with lock
*Decorative frame
*Castors
*Additional drawers on rails, max. capacity of drawers per fridge: 8 drawers
*Additional length and cross dividers
*Top drawer lockble
*Shelf 52,7 x 39 cm on rails or brackets (max. loading capacity: 40 kg)
*LED illumination mounted at side wall
*Melt water tray for manual emptying
Capacity | 460 l |
---|---|
Temperature setting | +2 to +15 °C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 190 Watts |
Average consumption | 0,91 KWh / 24 h |
Overall dimensions incl. distance from wall | 74 x 79,5 x 181 (w x d x h in cm) |
Interior dimensions | 60 x 57 x 128 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 74 x 144 (w x d in cm) |
Drawer inner dimensionns | 57 x 43 x 5,6 (w x d x h in cm) |
Loading capacity per drawer | 24 kg |
Weight | 130 kg / 143 kg (net / gross) |
Product information
Operating instructions
Please note:
You will find the information about the refrigerant used in your unit on the type plate inside the unit (R134a or R600a)
Operating instructions MED 468 ULTIMATE
Pharmaceutical RefrigeratorMED 340 ULTIMATE (on request)
according to DIN 58345
The pharmaceutical fridge features 9 vertically adjustable drawers made of plastic as standard equipment. The drawers rest on telescopic runners and have a locking element. Each drawer has 2 adjustable length dividers and 9 adjustable cross dividers.

*PRO-ACTIVE- Control:
Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors.
*Touch-Display, elegant glass design, capacitive
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*9 drawers, height adjustable
*Individual drawer division with adjustable length and cross dividers.
*Recirculating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Automatic defrosting
*Melt water evaporation
*Easy-to-read LED temperature display
*Easy accessible control panel with key switch
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Safety control prevents freezing
*Optical and acoustical alarm including power failure alarm
*Potential free contact for alarm transmission
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH Datanet
*Lockable door
*Glass door with lock
*Decorative frame
*Castors
*Additional drawers on rails, max. capacity of drawers per fridge: 8 drawers
*Additional length and cross dividers
*Top drawer lockble
*Shelf 52,7 x 39 cm on rails or brackets (max. loading capacity: 40 kg)
*LED illumination mounted at side wall
*Melt water tray for manual emptying
Capacity | 330 l |
---|---|
Temperature setting | +2 to +15 °C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 108 Watts |
Average consumption | 0,82 KWh / 24 h |
Overall dimensions incl. distance from wall | 67 x 63,5 x 128 (w x d x h in cm) |
Interior dimensions | 53 x 45 x 128 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 67 x 126 (w x d in cm) |
Drawer inner dimensionns | 50 x 32 x 5,6 (w x d x h in cm) |
Loading capacity per drawer | 16 kg |
Weight | 100 kg / 1113 kg (net / gross) |
Product information
Operating instructions
Please note:
You will find the information about the refrigerant used in your unit on the type plate inside the unit (R134a or R600a)
Operating instructions MED 340 ULTIMATE
Pharmaceutical RefrigeratorMED 288 ULTIMATE (on request)
according to DIN 58345
The pharmaceutical fridge features five vertically adjustable drawers made of plastic as standard equipment. The drawers rest on telescopic runners and have a locking element. Each drawer has 2 adjustable length dividers and 9 adjustable cross dividers.

*PRO-ACTIVE- Control:
Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors.
*Touch-Display, elegant glass design, capacitive
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*5 drawers, height adjustable
*Individual drawer division with adjustable length and cross dividers.
*Recirculating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Automatic defrosting
*Melt water evaporation
*Easy-to-read LED temperature display
*Easy accessible control panel with key switch
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Safety control prevents freezing
*Optical and acoustical alarm including power failure alarm
*Potential free contact for alarm transmission
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH Datanet
*Lockable door
*Glass door with lock
*Decorative frame
*Castors
*Additional drawers on rails, max. capacity of drawers per fridge: 8 drawers
*Additional length and cross dividers
*Top drawer lockble
*Shelf 52,7 x 39 cm on rails or brackets (max. loading capacity: 40 kg)
*LED illumination mounted at side wall
*Melt water tray for manual emptying
Capacity | 280 l |
---|---|
Temperature setting | +2 to +15 °C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 100 Watts |
Average consumption | 0,69 KWh / 24 h |
Overall dimensions incl. distance from wall | 67 x 75 x 133 (w x d x h in cm) |
Interior dimensions | 53 x 50 x 100 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 67 x 135 (w x d in cm) |
Drawer inner dimensionns | 50 x 32 x 5,6 (w x d x h in cm) |
Loading capacity per drawer | 16 kg |
Weight | 75 kg / 88 kg (net / gross) |
Product information
Operating instructions
Please note:
You will find the information about the refrigerant used in your unit on the type plate inside the unit (R134a or R600a)
Operating instructions MED 288 ULTIMATE
PRO-ACTIVE

*Reduction in power consumption by up to 60%
*Faster response times in case of impending faults thanks to proactive alerts
*Data documentation can be read via USB interface with KIRSCH Datanet software
*Reduction in temperature deviations in the refrigerated compartment
*Maximum storage safety due to perfectly coordinated components
*Including the benefits of the ESSENTIAL line
FROSTER BL 730 PRO-ACTIVE
according to DIN 58375
Selected models can be fitted with a water-cooled refrigeration machine on request. The generated heat gets derived into a cold water cycle, which is already installed in the device. This provides thermal relief in the installation room.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*5 aluminium drawers
*Castors
*Comfort controller
*Micro-processor controlled temperature and thawingregulation to maximize temperature stability
*Battery for power failure alarm
*Heated door frame
*Re-circulating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memory
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Potential free contact for alarm transmission
*Lockable door
*Additional drawer made of aluminium
*Adjustable feet to compensate for uneven floors.
*Length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawerShelf 59,7 x 65 cm with mounting brackets or rails
*Baskets with rails 60 x 65 x 10 cm
*Aluminium tray with rails 60 x 65 x 2,5 cm
*GSM-Module
*Outer housing in stainless steel 4301, brushed
*Pen-Recording thermometer for placing loosely inside appliance with waxed paper strips
*Disc-type pen recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 700 l |
---|---|
Temperature setting | -32°C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 790 Watts |
Average consumption | 11,1 KWh / 24 h |
Overall dimensions incl. distance from wall | 77 x 98 x 195,5 (w x d x h in cm) |
Interior dimensions | 62 x 77 x 140 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 77 x 166 (w x d in cm) |
Drawer inner dimensionns | 56 x 60 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 202 kg / 237 kg (net / gross) |
FROSTER BL 650 PRO-ACTIVE
according to DIN 58375
Storage temperature of this freezer is -41°C. A two-stage refrigeration machine generates the necessary cooling so that this temperature is kept constant. This enables operation of the freezer in ambient temperatures of up to +32°C.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*5 stainless steel drawers
*Comfort controller
*Micro-processor controlled temperature and thawing
*regulation to maximize temperature stabilityBattery for power failure alarm
*Heated door frame
*Re-circulation air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memory
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Potential free contact for alarm transmission
*Lockable door
*Drawer insert/dividers for stainless steel drawer
*GSM-Module
*PC-KIT-NET (Network capable version)
*Disc-type pen recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 650 l |
---|---|
Temperature setting | -41°C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 990 Watts |
Average consumption | 14,32 KWh / 24 h |
Overall dimensions incl. distance from wall | 83 x 102 x 197 (w x d x h in cm) |
Interior dimensions | 62 x 76 x 131 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 83 x 177 (w x d in cm) |
Drawer inner dimensionns, upper drawers | 59 x 56 x 22 (w x d x h in cm) |
Drawer inner dimensionns, 4 drawers below | 59 x 62 x 22 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 202 kg / 237 kg (net / gross) |
FROSTER BL 530 PRO-ACTIVE
according to DIN 58375
For all blood plasma freezers a PC-Kit is available for temperature evaluation, monitoring and documentation. Monitoring can also be done with the KIRSCH-DATANET Software-package. You find more information on this software in the corresponding description “KIRSCH-PC-KIT”.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*5 aluminium drawers
*Castors
*Comfort controller
*Micro-processor controlled temperature and thawing
*regulation to maximize temperature stability
*Battery for power failure alarmHeated door frame
*Re-circulation air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Height-adjustable drawers
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memo
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Potential free contact for alarm transmission
*Lockable door
*Additional drawer made of aluminium
*Adjustable feet to compensate for uneven floors.
*Length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawer
*Shelf 59,7 x 45 cm with mounting brackets or rails
*Baskets with rails 60 x 45 x 10 cm
*Aluminium tray with rails 60 x 40 x 2,5 cm
*GSM-Module
*Outer housing in stainless steel 4301, brushed
*Pen-Recording thermometer for placing loosely inside appliance with waxed paper strips
*Disc-type pen recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 500 l |
---|---|
Temperature setting | -32°C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 740 Watts |
Average consumption | 10,81 KWh / 24 h |
Overall dimensions incl. distance from wall | 77 x 76 x 195,5 (w x d x h in cm) |
Interior dimensions | 62 x 56 x 140 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 77 x 144 (w x d in cm) |
Drawer inner dimensionns | 56 x 39 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 161 kg / 183 kg (net / gross) |
FROSTER BL 330 PRO-ACTIVE
according to DIN 58375
This model features 4 vertically adjustable drawers made of aluminium which rest on telescopic runners. Drawers made of stainless steel are optionally available. We also supply dividers for a neatly and clearly arranged storage of the goods for both types of drawers.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*4 aluminium drawers
*Comfort controller
*Micro-processor controlled temperature and thawingregulation to maximize temperature stability
*Battery for power failure alarm
*Heated door frame
*Re-circulating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memory
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Potential free contact for alarm transmission
*Lockable door
*Castors*Length and cross dividers
*Additional drawer made of aluminium
*Drawer made of stainless steel instead of aluminium
*Shelf 52 x 42 cm with mounting brackets or rails
*Baskets with rails 56 x 40 x 10 cm
*Drawer insert/dividers for stainless steel drawer
*GSM-Module
*PC-KIT-NET (Network capable version)
*Pen-Recording thermometer for placing loosely inside appliance with 2 waxed paper strips
*Disc-type pen recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens (refrigerator height then 131 cm)
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 300 l |
---|---|
Temperature setting | -32°C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 550 Watts |
Average consumption | 6,59 KWh / 24 h |
Overall dimensions incl. distance from wall | 74 x 78 x 159 (w x d x h in cm) |
Interior dimensions | 59 x 52 x 95 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 74 x 142 (w x d in cm) |
Drawer inner dimensionns | 50 x 37 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 120 kg / 135 kg (net / gross) |
FROSTER BL 180 PRO-ACTIVE
according to DIN 58375
All KIRSCH Blood Plasma Freezers are fitted with an automatic rapid defrosting system. The defrosting process is thermically monitored and temporarily limited. This prevents freezing of the interior and the temperature of the appliance’s contents is being kept constant in accordance with applicable regulations.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*3 aluminium drawers
*Comfort controller
*Micro-processor controlled temperature and thawingregulation to maximize temperature stability
*Battery for power failure alarm
*Heated door frame
*Re-circulating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memory
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Potential free contact for alarm transmission
*Lockable door
*Castors
*Additional length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawer
*GSM-Module
*PC-KIT-NET (Network capable version)
*Pen-Recording thermometer for placing loosely inside appliance with 2 waxed paper strips
*Disc-type pen recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens (refrigerator height then 131 cm)
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 170 l |
---|---|
Temperature setting | -41°C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 453 Watts |
Average consumption | 6,54 KWh / 24 h |
Overall dimensions incl. distance from wall | 70 x 77 x 122 (w x d x h in cm) |
Interior dimensions | 55 x 52 x 60 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 70 x 136 (w x d in cm) |
Drawer inner dimensionns | 50 x 32 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 100 kg / 110 kg (net / gross) |
FROSTER BL 178 PRO-ACTIVE
according to DIN 58375
All KIRSCH Blood Plasma Freezers are fitted with an automatic rapid defrosting system. The defrosting process is thermically monitored and temporarily limited. This prevents freezing of the interior and the temperature of the appliance’s contents is being kept constant in accordance with applicable regulations.

*PRO-ACTIVE- Control:Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
*3 aluminium drawers
*Comfort controller
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Battery for power failure alarm
*Heated door frame
*Re-circulating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Rapid defrosting
*Melt water evaporation
*Easy accessible control panel with key switch
*Easy-to-read LED temperature display
*Optical and acoustical warning including power failure alarm
*Minimum/maximum temperature memory
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*Potential free contact for alarm transmission
*Lockable door
*Castors
*Additional length and cross dividers
*Drawer made of stainless steel instead of aluminium
*Drawer insert/dividers for stainless steel drawer
*GSM-Module
*PC-KIT-NET (Network capable version)
*Pen-Recording thermometer for placing loosely inside appliance with 2 waxed paper strips
*Disc-type pen recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens (refrigerator height then 131 cm)
*Temperature probe PT 100 or PT 1000, 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 170 l |
---|---|
Temperature setting | -32°C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 500 Watts |
Average consumption | 4,54 KWh / 24 h |
Overall dimensions incl. distance from wall | 70 x 77 x 122 (w x d x h in cm) |
Interior dimensions | 55 x 52 x 60 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 70 x 136 (w x d in cm) |
Drawer inner dimensionns | 50 x 34 x 10 (w x d x h in cm) |
Loading capacity per drawer | 50 kg |
Weight | 100 kg / 110 kg (net / gross) |
Pharmaceutical Freezers
Thanks to their robust design and technical equipment, pharmaceutical freezers from KIRSCH are top-quality products that need an absolute minimum of routine maintenance and are produced by high-volume methods.
Model Specific Features
They stand out particularly thanks to their thick housing insulation made of high-quality, pressure-foamed, environmentally compatible material and guarantee low energy consumption.Depending on the individual model, the operating temperature is maintained automatically either by an interior thermostat or an electronic micro-processor controlled temperature regulator with digital display, even in the event of changing ambient temperatures.

- TemperatureThere are large temperature ranges available for storing goods: from -5 to -25°C or from -15 to -22°C.
- IsolationThe housing is insulated with particulary good, environmentally-compatible pressure foam material to guarantee low energy consumption levels.
- Interior Container The interior is made of impact-resistant plastic with moulded supports.
- Interior EquipmentEquipped with drawers/shelves
- DoorHeated door frame. The lockable door has a plastic magnetic sealing frame that is easy to replace. Door hinge on the right as standard, however this can be changed to the left.
PRO-ACTIVE

*Reduction in power consumption by up to 60%
*Faster response times in case of impending faults thanks to proactive alerts
*Data documentation can be read via USB interface with KIRSCH Datanet software
*Reduction in temperature deviations in the refrigerated compartment
*Maximum storage safety due to perfectly coordinated components
*Including the benefits of the ESSENTIAL line
Pharmaceutical Freezer
FROSTER MED 95 PRO-ACTIVE
The Pharmaceutical Freezer FROSTER-MED-95 is being used as an integrated or undercounter type freezer or as a stand-alone model. The compressor is dynamic ventilated. Air supply and discharge is done via a ventilating grille at the front. This permits an effortless installation (also as an undercounter type)
-
- Medikamenten-Gefrierschrank-Froster-Med-95
*PRO-ACTIVE- Control:
Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors1 drawer and 2 shelves
*Undercounter type
*Heated door frame
*Rapid freezing cycle
*Digital temperature display
*Key switch
*Minimum/Maximum temperature memory
*Optical and acoustic warning device
*Potential free contact and interface RS485
*Low-noise compressor
*Lockable door
*Work surface
*Decorative frame
*Door fitting
*Castors
*Additional drawer or shelf
*Warning in case of power failure (optical and acoustic)
*GSM-Module
*PC-KIT-NET (Network capable version)
*Pen-recording thermometer for placing loosely inside appliance with 2 waxed paper strips
*Temperature probe PT 100 or PT 1000,
4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 95 l | |||
---|---|---|---|---|
Temperature setting | -5 to -25 °C | |||
Voltage | 220 - 240 V | |||
Frequency | 50 Hz | |||
Power consumption | 123 Watts | |||
Average consumption | 1,33 KWh / 24 h | |||
Overall dimensions incl. distance from wall | 54 x 54 x 82 (w x d x h in cm) | |||
Interior dimensions | 44 x 42 x 47 (w x d x h in cm) | |||
Overall dimensions with door opened at 90° | 54 x 105,5 (w x d in cm) | |||
Drawer inner dimensionns | 40,8 x 32 x 5,6 (w x d x h in cm) | |||
Shelf dimensions | 43,8 x 36 (w x d in cm) | |||
Loading capacity per drawer | 13 kg | |||
Weight | 50 kg / 54 kg (net / gross) |
ESSENTIAL

*Your entry into KIRSCH quality
*Maximum reliability
*RobustnessTemperature stability
*Maximum safety
Pharmaceutical FreezerESSENTIAL FROSTER 70
This pharmaceutical freezer is mainly being used as a built-in device. If the static ventilation is insufficient a refrigeration machine ventilator can optionally be integrated.
-
- ESSENTIAL_FROSTER_70-mittel
*4 shelves
*Undercounter type
*Heated door frame
*Actual value thermometer
*Lockable door
*Decorative frame
*Door fitting
*Cooling machine ventilator when the static ventilation is not sufficient if appliances are integrated in cupboards
*GSM-Module
*Pen-recording thermometer for placing loosely inside appliance with 2 waxed paper strips
*DATALOG-USB-MONITORING or DATALOG-NET
*Temperature probe PT 100 or PT 1000,
4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Capacity | 70 l | |||
---|---|---|---|---|
Temperature setting | -15 to -22 °C | |||
Voltage | 220 - 240 V | |||
Frequency | 50 / 60 Hz | |||
Power consumption | 100 Watts | |||
Average consumption | 1,98 KWh / 24 h | |||
Overall dimensions incl. distance from wall | 47 x 51 x 74 (w x d x h in cm) | |||
Interior dimensions | 35 x 41 x 55 (w x d x h in cm) | |||
Overall dimensions with door opened at 90° | 47 x 96 (w x d in cm) | |||
Shelf dimensions | 20,5 x 35,2 resp. 31,5 x 35,3 (w x d in cm) | |||
Loading capacity per drawer | 25 kg | |||
Weight | 35 kg / 39 kg (net / gross) |
Product information
Laboratory Refrigerators

Even temperature distribution and homogeneity in the interior
Every KIRSCH laboratory refrigerator is reliable and creates optimal conditions for storing your sensitive goods. Our laboratory refrigerators are world leaders when it comes to temperature constancy.
ADVANTAGES
Being a manufacturer enables us steady, on-going development of our products. Each unit consists of a robust housing and high-quality components Made in Germany. This guarantees reliability and longevity, which ultimately saves your budget.
Depending on the individual model type, the refrigerators also feature:
*PRO-ACTIVE Control
*Recirculating air-cooling
*Optimized ventilation plates to minimize interior temperature differences
*Automatical defrosting and melt water evaporation
*Height- adjustable shelves
*Easy accessible control panel with key switch
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Easy-to-read LED temperature display
*Safety device to prevent freezing
*Optical and acoustical alarm
*Minimum/maximum temperature memory
*Potential free contact for alarm transmission
*Data documentation can be read via USB interface with KIRSCH Datanet software.
*RS-485 interface for computer based temperature documentation
*Low-noise compressor
ULTIMATE

-
- 1634705069018
*Touch-Display, elegant glass design
*Simple operation via a capacitive touch display
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*Digital data documentation with KIRSCH Datanet software
*Quick-start
*Touch operation with laboratory gloves is possible
*Intuitive help with alarm messages and troubleshooting in plain text
*Operation via remote control is possible
*Including the benefits of the PRO-ACTIVE line
Laboratory RefrigeratorLABO 720 ULTIMATE
This laboratory fridge has 5 vertically adjustable and plastic coated shelves which rest on mountings. This laboratory refrigerator can optionally be fitted with a glass door.

*PRO-ACTIVE- Control:
Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors.
*Touch-Display, elegant glass design, capacitive
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*5 shelves, height-adjustable
*Castors
*Re-circulating air cooling
*Warning in case of power failure (optical and acoustic)
*Optimized ventilation plates to minimize interior temperature differences
*Easy-to-read LED temperature display
*Automatical defrosting and melt water evaporationEasy accessible control panel with key switch
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Minimum/maximum temperature memory
*Safety device to prevent freezing
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH Datanet
*Potential free contact for alarm transmission
*Low-noise compressor
*Lockable door
*Insulating glass door with lock
*Adjustable feet to compensate for uneven floors.
*Shelves on mountings or support rails
*Additional drawers on telescopic runners (57x40x5,6 cm): max. 12 pieces
*Additional lenght and cross dividers for drawers
*Aluminium trays or baskets with support rails
*LED illumination mounted at side wall
*Meltwater tray for manual emptying
*Cooling machine with cold water connection
*Cooling machines with natural refrigerant
*Outer panels in stainless steel 4301
Capacity | 700 l |
---|---|
Temperature setting | +2 to +15 °C |
Voltage | 220 - 240 V |
Frequency | 50 Hz |
Power consumption | 250 Watts |
Average consumption | 1,55 KWh / 24 h |
Overall dimensions incl. distance from wall | 77 x 98 x 195,5 (w x d x h in cm) |
Interior dimensions | 62 x 77 x 140 (w x d x h in cm) |
Overall dimensions with door opened at 90° | 77 x 165 (w x d in cm) |
Drawer inner dimensionns | 57 x 60 x 6 (w x d x h in cm) |
Loading capacity per drawer | 24 kg |
Weight | 164 kg / 190 kg (net / gross) |
Product information
Operating instructions
Please note:
You will find the information about the refrigerant used in your unit on the type plate inside the unit (R134a or R600a)
Operating instructions MED 720 ULTIMATE
Laboratory Refrigerator
LABO 720 CHROMAT ULTIMATE
This laboratory fridge has a glass door, an integrated power outlet strip with 3 sockets and a cable bushing with a diameter of approximately 7 cm fitted as standard. The cable bushing is located in the middle of the right side panel.
* Pic. with aluminium basket (optional equipment, not standard configuration)

*PRO-ACTIVE- Control:
Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors.
*Touch-Display, elegant glass design, capacitive
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*5 shelves, height-adjustable
*Castors
*Warning in case of power failure (optical and acoustic)
*Insulating glass door and interior light
*Built-in 3-way-socket
*Access port for cables and probes
*diameter app. 7 cm
*Re-circulating air cooling
*Optimized ventilation plates to minimize interior temperature differences
*Easy-to-read LED temperature display
*Automatical defrosting and melt water evaporation
*Rapid defrosting
*Easy accessible control panel with key switch
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Safety device to prevent freezing
*Optical and acoustical alarm
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH Datanet
*Low-noise compressor
*Potential free contact for alarm transmission
*Low-noise compressor
*Lockable door
*Insulating glass door
*Adjustable feet to compensate for uneven floors.
*Lock for glass door
*Additionals shelves on mountings or support rails
*Additional drawers on telescopic runner (57x40x5,6 cm): max. 12 pieces
*Additional lenght and cross dividers for drawers
*Aluminium trays or baskets with support rails
*Meltwater tray for manual emptying
*Cooling machine with cold water connection
*Cooling machines with natural refrigerant
*Outer panels in stainless steel 4301
Capacity | 500 l | |||
---|---|---|---|---|
Temperature setting | +2 to +15 °C | |||
Voltage | 220 - 240 V | |||
Frequency | 50 Hz | |||
Power consumption | 260 Watts | |||
Average consumption | 1,5 KWh / 24 h | |||
Overall dimensions (incl. distance from wall) | 77 x 76 x 196 (W x D x H in cm) | |||
Interior dimensions | 60 x 57 x 140 (w x d x h in cm) | |||
Exterior dimensions with door Exterior dimensions with door opened at 90° | 74 x 144 (w x d in cm) | |||
Shelf inner dimensions | 57 x 39 x 140 (w x d in cm) | |||
Max. loading capacity per shelf | 24 kg | |||
Weight | 120 kg / 174 kg (net / gross) |
Product information
Operating instructions
Please note:
You will find the information about the refrigerant used in your unit on the type plate inside the unit (R134a or R600a)
Operating instructions LABO 720 CHROMAT ULTIMATE
Laboratory RefrigeratorLABO 520 ULTIMATE
This laboratory refrigerator has 5 vertically adjustable and plastic coated shelves which rest on mountings. The shelves can optionally rest onsupport rails. Drawers, aluminium trays and wire baskets are available as well.

*PRO-ACTIVE- Control:
Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors.
*Touch-Display, elegant glass design, capacitive
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*5 shelves, height-adjustable
*Castors
*Re-circulating air cooling
*Warning in case of power failure (optical and acoustic)
*Optimized ventilation plates to minimize interior temperature differences
*Easy-to-read LED temperature display
*Automatical defrosting and melt water evaporation
*Easy accessible control panel with key switch
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Minimum/maximum temperature memory
*Safety device to prevent freezing
*Optical and acoustical alarm
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH Datanet
*Potential free contact for alarm transmission
*Low-noise compressor
*Lockable door
*Insulating glass door with lock
*Adjustable feet to compensate for uneven floors.
*Shelves on mountings or support rails
*Additional drawers on telescopic runner (57x40x5,6 cm): max. 12 pieces
*Additional lenght and cross dividers for drawers
*Aluminium trays or baskets with support rails
*LED illumination mounted at side wall
*Meltwater tray for manual emptying
*Cooling machine with cold water connection
*Cooling machines with natural refrigerant
*Outer panels in stainless steel 4301
Capacity | 500 l | |||
---|---|---|---|---|
Temperature setting | +2 to +15 °C | |||
Voltage | 220 - 240 V | |||
Frequency | 50 Hz | |||
Power consumption | 260 Watts | |||
Average consumption | 1,5 KWh / 24 h | |||
Overall dimensions (incl. distance from wall) | 77 x 76 x 196 (W x D x H in cm) | |||
Interior dimensions | 60 x 57 x 140 (w x d x h in cm) | |||
Exterior dimensions with door Exterior dimensions with door opened at 90° | 74 x 144 (w x d in cm) | |||
Shelf inner dimensions | 57 x 39 x 140 (w x d in cm) | |||
Max. loading capacity per shelf | 24 kg | |||
Weight | 120 kg / 174 kg (net / gross) |
Product information
Operating instructions
Please note:
You will find the information about the refrigerant used in your unit on the type plate inside the unit (R134a or R600a)
Operating instructions LABO 520 ULTIMATE
Laboratory RefrigeratorLABO 468 ULTIMATE (on request)
This laboratory fridge has 4 vertically adjustable and plastic coated shelves which rest on mountings. The shelves can optionally rest on support rails. Drawers, aluminium trays and wire baskets are available as well.

*PRO-ACTIVE- Control:
Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors.
*Touch-Display, elegant glass design, capacitive
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*4 shelves, height-adjustable
*Re-circulating air cooling
*Warning in case of power failure (optical and acoustic)
*Optimized ventilation plates to minimize interior temperature differences
*Easy-to-read LED temperature display
*Automatical defrosting and melt water evaporation
*Easy accessible control panel with key switch
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Safety device to prevent freezing
*Optical and acoustical alarm
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH Datanet
*Potential free contact for alarm transmission
*Low-noise compressor
*Lockable door
*Insulating glass door
*Decorative frame
*Lock for glass door
*60 Hz cooling machine upon request
*Castors
*Door fitting
*Condensate container
*Plastic-drawer on roller runners
*Aluminium-drawer on roller runners
*Stainless steel-drawer
*dditional shelf on rails or overlays
*Additional lenght and cross dividers for drawer
*LED illumination mounted at side wall
Capacity | 500 l | |||
---|---|---|---|---|
Temperature setting | +2 to +15 °C | |||
Voltage | 220 - 240 V | |||
Frequency | 50 Hz | |||
Power consumption | 260 Watts | |||
Average consumption | 1,5 KWh / 24 h | |||
Overall dimensions (incl. distance from wall) | 77 x 76 x 196 (W x D x H in cm) | |||
Interior dimensions | 60 x 57 x 140 (w x d x h in cm) | |||
Exterior dimensions with door Exterior dimensions with door opened at 90° | 74 x 144 (w x d in cm) | |||
Shelf inner dimensions | 57 x 39 x 140 (w x d in cm) | |||
Max. loading capacity per shelf | 24 kg | |||
Weight | 120 kg / 174 kg (net / gross) |
Product information
Operating instructions
Please note:
You will find the information about the refrigerant used in your unit on the type plate inside the unit (R134a or R600a)
Operating instructions LABO 468 ULTIMATE
Laboratory RefrigeratorLABO 340 ULTIMATE (on request)
This laboratory fridge comes with 1 drawer and 4 shelves as standard. The refrigerator can also be equipped with power failure alarm against surcharge.

*PRO-ACTIVE- Control:
Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors.
*Touch-Display, elegant glass design, capacitive
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*1 drawer and 4 shelves, height-adjustable
*Re-circulating air cooling
*Warning in case of power failure (optical and acoustic)
*Optimized ventilation plates to minimize interior temperature differences
*Easy-to-read LED temperature display
*Automatical defrosting and melt water evaporation
*Easy accessible control panel with key switch
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Minimum/maximum temperature memory
*Safety device to prevent freezing
*Optical and acoustical alarm
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH Datanet
*Potential free contact for alarm transmission
*Lockable door
*Insulating glass door
*Lock for glass door
*Decorative frame
*Castors
*Additional shelves on mountings or telescopic runners
*Additional drawers on telescopic runners: max. 10 pieces
*Additional lenght and cross dividers for drawer
*LED illumination mounted at side wall
*Meltwater tray for manual emptying
Capacity | 500 l | |||
---|---|---|---|---|
Temperature setting | +2 to +15 °C | |||
Voltage | 220 - 240 V | |||
Frequency | 50 Hz | |||
Power consumption | 260 Watts | |||
Average consumption | 1,5 KWh / 24 h | |||
Overall dimensions (incl. distance from wall) | 77 x 76 x 196 (W x D x H in cm) | |||
Interior dimensions | 60 x 57 x 140 (w x d x h in cm) | |||
Exterior dimensions with door Exterior dimensions with door opened at 90° | 74 x 144 (w x d in cm) | |||
Shelf inner dimensions | 57 x 39 x 140 (w x d in cm) | |||
Max. loading capacity per shelf | 24 kg | |||
Weight | 120 kg / 174 kg (net / gross) |
Product information
Operating instructions
Please note:
You will find the information about the refrigerant used in your unit on the type plate inside the unit (R134a or R600a)
Operating instructions LABO 340 ULTIMATE
Laboratory RefrigeratorLABO 288 ULTIMATE (on request)
This laboratory fridge comes with 3 shelves as standard. The refrigerator can also be equipped with power failure alarm against surcharge.
*Pic. with 4 shelves (not standard equipment)

*PRO-ACTIVE- Control:
Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors.
*Touch-Display, elegant glass design, capacitive
*Access control with a log
*Graphical display of the temperature curve and min/max temperature
*3 drawer, height-adjustable
*Re-circulating air cooling
*Warning in case of power failure (optical and acoustic)
*Optimized ventilation plates to minimize interior temperature differences
*Easy-to-read LED temperature display
*Automatical defrosting and melt water evaporation
*Easy accessible control panel with key switch
*Micro-processor controlled temperature and thawing regulation to maximize temperature stability
*Minimum/maximum temperature memory
*Safety device to prevent freezing
*Optical and acoustical alarm
*Digital data documentation via PC-KIT-NET oder USB interface and software KIRSCH Datanet
*Potential free contact for alarm transmission
*Lockable door
*Insulating glass door
*Lock for glass door
*Decorative frame
*Castors
*Additional shelves on mountings or telescopic runners
*Additional drawers on telescopic runners: max. 10 pieces
*Additional lenght and cross dividers for drawer
*LED illumination mounted at side wall
*Meltwater tray for manual emptying
Capacity | 500 l | |||
---|---|---|---|---|
Temperature setting | +2 to +15 °C | |||
Voltage | 220 - 240 V | |||
Frequency | 50 Hz | |||
Power consumption | 260 Watts | |||
Average consumption | 1,5 KWh / 24 h | |||
Overall dimensions (incl. distance from wall) | 77 x 76 x 196 (W x D x H in cm) | |||
Interior dimensions | 60 x 57 x 140 (w x d x h in cm) | |||
Exterior dimensions with door Exterior dimensions with door opened at 90° | 74 x 144 (w x d in cm) | |||
Shelf inner dimensions | 57 x 39 x 140 (w x d in cm) | |||
Max. loading capacity per shelf | 24 kg | |||
Weight | 120 kg / 174 kg (net / gross) |
Product information
Operating instructions
Please note:
You will find the information about the refrigerant used in your unit on the type plate inside the unit (R134a or R600a)
Operating instructions LABO 340 ULTIMATE